Repair Items from HMI/Touch Screen

Aug 27, 2025

Markem-Imaje Smartdate x60 HMI

Manufacturer : Markem-Imaje

Markem-Imaje Smartdate x60 HMI

We carried out detailed testing of a Markem-Imaje Smartdate X60 HMI which was experiencing display malfunction and unstable operation. Through micro-level diagnosis we identified faulty ICs, damaged capacitors, and power regulation faults. After replacing defective parts and completing performance testing, the HMI regained stable performance and is now suitable for reliable industrial use.
Note: We are not manufacturers, we only repair.

Aug 18, 2025

EXOR eSMART07M HMI

Manufacturer: EXOR

EXOR eSMART07M HMI

We tested an EXOR eSMART07M HMI that showed booting errors and touchscreen response issues. Circuit-level analysis revealed corrupted memory ICs and defective power components. After repairs and final testing, the HMI became fully functional and reliable for industrial applications.
Note: We are not manufacturers, we only repair.

Jan 13, 2025

Siemens Simatic HMI

Manufacturer : Siemens

Siemens Simatic HMI

We received a Siemens Simatic HMI with communication failure and unstable display signals. Testing and diagnosis showed faulty drivers, regulator issues, and damaged capacitors. After component replacement and repeated testing, the HMI achieved proper working condition.
Note: We are not manufacturers, we only repair.

Jan 9, 2025

Monitouch TS1070 HMI

Manufacturer : Monitouch

Monitouch TS1070 HMI

We worked on a Monitouch TS1070 HMI with screen flickering and keypad malfunction. Testing and circuit tracing revealed faulty driver ICs and shorted capacitors. After repair and performance checks, the panel delivered stable and smooth operation.
Note: We are not manufacturers, we only repair.

Jan 9, 2025

T Line Etop05-0945 Operator Interface Panel

Manufacturer : T Line

T Line Etop05-0945 Operator Interface Panel

We tested a T Line Etop05-0945 Panel that had display blackouts and unstable signals. Micro-level checks showed damaged ICs and capacitor failure. After precision replacement and testing, the panel became fully operational.
Note: We are not manufacturers, we only repair.

Jan 9, 2025

MITSUBISHI ELECTRIC GS2110-WTBD-N HMI

Manufacturer : Mitshubishi Electric

MITSUBISHI ELECTRIC GS2110-WTBD-N HMI

We tested a Mitsubishi Electric GS2110-WTBD-N HMI that faced power-up failure and unresponsive touch panel. Detailed analysis detected faulty flash memory and regulator faults. After replacing defective parts and conducting final testing, the unit regained reliable performance.
Note: We are not manufacturers, we only repair.

Aug 16, 2024

Baur IRG 32 panel

Manufacturer : Baur

Baur IRG 32 panel

We carried out testing on a Baur IRG 32 Panel that had control instability and power faults. Diagnosis revealed faulty regulators and defective ICs. After repairs and load testing, the panel performed reliably in simulated conditions.
Note: We are not manufacturers, we only repair.

Dec 15, 2023

Siemens SIMATIC KP700 Comfort HMI Display

Manufacturer : Siemens

Siemens SIMATIC KP700 Comfort HMI Display

We tested a Siemens SIMATIC KP700 Comfort HMI Display which had touchscreen failure and unstable backlight. Diagnosis showed driver faults and capacitor damage. After replacement and company-level testing, the HMI regained reliable operation for industrial use.
Note: We are not manufacturers, we only repair.

Dec 15, 2023

Allen-Bradly Panel View 550

Manufacturer : Allen-Bradly

Allen-Bradly Panel View 550

We carried out testing on an Allen-Bradley PanelView 550 that showed boot failure and contrast display issues. Analysis revealed faulty driver ICs and power regulation problems. After repair and repeated testing, the HMI delivered dependable performance.
Note: We are not manufacturers, we only repair.

Dec 15, 2023

Windtec Operating Panel

Manufacturer : Windtec

Windtec Operating Panel

We tested a Windtec Operating Panel that had communication errors and display freezing. Testing confirmed defective capacitors and corrupted ICs. After component-level repair and repeated testing, the panel achieved stable operation.
Note: We are not manufacturers, we only repair.