Repair Items from HMI/Touch Screen
Dec 15, 2020
Mettler Toledo HMI (SRN. B340848276)
Manufacturer : Mettler Toledo
We repair Mettler Toledo HMI (Serial: B340848276) which had frequent freezing and touchscreen malfunction. During circuit testing, damaged ICs and faulty capacitors were identified. These issues disrupted smooth functioning of the HMI. Our team carried out micro-level repairs and replaced the defective parts. After completing the repair, the unit was tested thoroughly for reliability. The HMI then worked smoothly with stable performance in its application.
Note: We are not manufacturers, we only repair.
Dec 15, 2020
Allen-Bradley Panel View Plus 1000
Manufacturer : Allen-Bradley
We repair Allen-Bradley PanelView Plus 1000 that suffered from booting issues and unresponsive touchscreen. Our engineers carried out detailed analysis and found damaged flash ICs and regulator faults. These defects caused the system to fail during operation. We replaced the defective ICs and repaired the regulator circuit. After the repair, the HMI was thoroughly tested for performance and stability. The unit delivered reliable operation and was ready for use in automation systems.
Note: We are not manufacturers, we only repair.
Dec 15, 2020
Level Indicator
Level Indicator
We repair Level Indicator which was showing incorrect readings and frequent signal loss. Through micro-level testing, we detected regulator faults and several defective electronic components. These issues affected the reliability of the indicator in its industrial application. We replaced the faulty parts and corrected the power regulation. The repaired unit was then tested in repeated cycles for stability. After successful verification, the level indicator achieved accurate and consistent performance.
Note: We are not manufacturers, we only repair.
Dec 15, 2020
Shimadzu LC-2030 Display
Manufacturer : Shimadzu
We repair Shimadzu LC-2030 Display that had unresponsive functions and backlight failure. The testing process revealed faulty memory sections and power circuit issues. These faults caused the display to remain inactive during usage. Our engineers performed component replacement and corrected the damaged circuitry. After repair, the display was tested multiple times under lab conditions. The Shimadzu display then performed reliably and was ready for accurate laboratory use.
Note: We are not manufacturers, we only repair.
Dec 15, 2019
Siemens SIMATIC PANEL
Manufacturer : Siemens
We repair Siemens SIMATIC Panel which had black screen issues and failed to respond to inputs. Detailed testing highlighted memory IC faults, damaged capacitors, and regulator problems. These caused malfunctions during automation processes. Our engineers carried out repairs with micro-level precision. After replacing the defective components, the panel was tested thoroughly. The SIMATIC panel then delivered smooth and reliable performance.
Note: We are not manufacturers, we only repair.
Dec 15, 2019
Collin Power Panel 300
Manufacturer : Collin
We repair Collin Power Panel 300 which was not powering on and had unstable communication. During testing, our engineers identified power regulation faults, damaged capacitors, and IC problems. These issues caused frequent errors in machine operation. We replaced the defective components and corrected the circuits. After the repair, the panel was tested under company-level standards. The unit achieved stable and reliable functionality for industrial use.
Note: We are not manufacturers, we only repair.
Dec 15, 2019
Mitsubishi Make HMI (Type - 06701C) (Type - 06701C, 602221103) (Name - E1032)
Manufacturer : Mitsubishi
We repair Mitsubishi Make HMI (Type - 06701C, 602221103, Name - E1032) that showed a black screen and unresponsive keys. Testing revealed faulty driver ICs and power supply faults in the unit. These issues made the HMI unusable in operations. We replaced the defective ICs and corrected the power section. After repair, the HMI underwent repeated testing under industrial load. The unit achieved stable functionality and was ready for industrial use.
Note: We are not manufacturers, we only repair.
Dec 15, 2019
Kaeser sigma control panel
Manufacturer : Kaeser
We repair Kaeser Sigma Control Panel that suffered from frequent shutdowns and communication errors. Our testing confirmed regulator faults, capacitor damage, and defective ICs. These issues disturbed smooth compressor operation. The faulty parts were replaced, and the circuits were corrected carefully. After repair, the panel was tested under industrial load conditions. The unit achieved stable and dependable performance.
Note: We are not manufacturers, we only repair.
Dec 15, 2019
Exter t100 HMI
Manufacturer : Beijer Electronics
We repair Exter T100 HMI that had a dead display and unresponsive keys. Circuit testing revealed defective driver ICs, faulty capacitors, and regulator problems. These faults prevented the HMI from operating correctly in its system. We carried out micro-level repairs and replaced damaged components. The HMI was then tested in multiple cycles for performance verification. After repair, the unit worked reliably with stable operation.
Note: We are not manufacturers, we only repair.
Dec 15, 2018
Elektronikon Controller (Atlas Copco)
Manufacturer : Atlas Copco
We repair Elektronikon Controller (Atlas Copco) that was not starting and showed unstable signals. Testing revealed defective capacitors, regulator issues, and IC failures. These prevented proper system operation in compressors. We carried out component replacement and corrected the power circuits. After multiple rounds of testing, the controller performed with stability. The repaired unit was ready for reliable industrial use.
Note: We are not manufacturers, we only repair.